Customization: | Available |
---|---|
After-sales Service: | Long Term |
Warranty: | Long Term |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Moving Hood Kiln
Kiln Features:
No. OF KILNS: | One | |
TYPE OF KILN: | Moving Hood Intermittent Kiln with Horizontal Afterburner and Down Draught System | |
MAXIMUM WORKING FIRING TEMP: Max Soaking Time at Max Operating Temperature: Firing Mode: |
1400°C (Design Safety factor to be included) 150 Minutes (Design Safety factor to be included) Normal and Regenerative |
|
TEMPERATURE UNIFORMITY: | ±5°C throughout the kiln at soak (Note: Measuring area should be outside the crucible and 150mm above floor level to top of crucible)in the useful loading area only | |
ATMOSPHERE: | Oxidizing at adjustable range of 0 to 5%. | |
FUEL: | LPG, 2 staged regulator 4kg to 1 kg /CM2 | |
ELECTRICAL SUPPLY: | 415V(+/-10%) Three Phase and Neutral | |
KILN USFELU VOLUME: | 69.3m³ | |
KILN USEABLE NTERNAL DIMENSIONS: | 6000(3 hearth x2000)*3,500*3,300mm (L*W*H) | |
KILN USEABLE EXTERNAL DIMENSIONS: | 9200*5600*4800mm (To be Finalized during GA drawing Review) Lining thick ness 350 mm to be reviewed with Fibre vendor based on the Design of LTT |
|
KILN AFTER BURNER SYSTEM DIMENSIONS: | 8000*1600*1600mm(To be Finalized during GA drawing Review) | |
KILN OVERALL WEIGHT | Approx 60TON (Inclusive of all with Lining moisture) | |
MAXIMUM WEIGHT OF WARE PER FIRE: VOC Flue gas burning- Modulating Control: |
Direct Load (SIC/ CG) : 10 MT Indirect Load or Product Load with Saggers : 24MT After burner about 800ºC-850ºC After burner in operation from start of cycle to 850 Deg or 900 Deg . |
|
KILN FIRING CYCLE: | Indirect Firing 1260mins (CG/SiC) Direct Firing 230mins (SiC) Direct Firing 2880Min(CG) As per Program cycles program can be fed into the system Very slow heating rate at the rate 40 deg/Hr can be achieved No sudden rise of temp inside kiln during slow heating cycles |
|
KILN LINING: | Kiln lining - 350MM and after burner is 150~200MM. Max allowed skin temperature is RT + 30 Deg | |
KILN HEARTH: | 2 Hearths with Flue Port and Exhaust passage Refractory Hearths Material specifications | |
T/C IN KILN: |
8 set -control / over temp. Duplex type . Specifications of shields and 'R' type thermocouples | |
T/C IN A/B: | 1 - control /1- over temp Duplex type, Specifications of "K" Typ | |
T/C IN REGENERATIVE BURNER EXHAUST | 8 monitor, specification K type | |
Zone wise control: | Independent or Multiple Control Zones Technology | |
KILN BURNERS: | 16 - 420kw rated Epsilon high velocity Regenerative Burners, complete with refractory flame brick, spark ignition and uv sensors Detail drawing to be shared before procurement. ENERGY SAVING of 30-35% SAVING can be achieved through Regenerative burners(Compared during Regenerative Mode only) |
|
Products Sintering | LTT AssurE correct Product Sintering For Direct & Indirect Firing Cycles as agreed | |
AFTERBURNERS: | 6 -- Epsilon hot air burners for modulating control with sic tubes, spark ignition and uv sensors. | |
HEATING SYSTEM: | Pulse Fired system, and flameless flame over 850ºC 8 Zone control |
|
PROGRAMME/CONTROL: | LTT E-smart System: Remote control available, Alarm messenger to appointed person. Cabinet comply to IP65 PLC based control system comprising of:- Kiln Mounted control panel containing a colour touch screen (15" High Brightness) and integrated computer including SCADA system and kiln over temperature controller, the touch screen will act as the main user interface. The screen allows programming of kilns firing cycles and provides real time and historic time reading, stamped plant alarms. PLC to be Allan Bradley. Emergency switches to be provided in all Electrical Panels All displays and control systems should be in English |
|
Access Control | Programmer Controllers with password Protection ,All Instrumentation Where Ever Applicable | |
Kiln Pressure Control system Auto | Two pressure transducers to monitor and record the pressure in the kiln chamber. | |
Electrical and LPG connections to Hood: | LPG Flexible Hose connection as Kiln hood is moving. Electrical Cables with Flexible cable tray to avoid damages to cabling and short circuit LPG hose pipe and electrical cable tray must be separate | |
Regenerative mode: | Regenerative, High Velocity, Pulsed Firing which is run until the volatile gases finish coming out to avoid the regen box damage caused by the maybe partial overheat, now the system is most efficient compared with other system . when the kiln run at 1400ºC the benefit from our flameless flame can be selected above 850ºC,the products will be not affected by high regenerative burners is that combustion air will be preheated up to 1000ºC, flameless flame can be selected above 850ºC,the products will be not affected by high temperature flame and very good temperature distribution. Flexibility for direct & indirect-For Better Energy saving. Heat recuperator for Kiln Burners in Normal Firing mode. --Only for After Burners. |
|
SAFETY INTERLOCKS: | The gas supply to the kiln is automatically shut off in accordance with EN746-2:- 1. High gas pressure. 2. Low gas pressure. 3. Low air pressure. 4. Over temperature setting is exceeded. 5. Loss of electrical power to kiln. 6. Over kiln pressure 7. Door Unlock 8. Kiln Not in hearth position 9. Regen box over temperature |
|
Main Gas Train Safety: | Pressure operated vent valve Sinon)Pressure operated vent valve (Sinon) 2 NOS-Solenoid safety shut off valve (Sinon) 1 Valve Passing System/Gas leak detection system |
|
After Gas Burner system | Pressure operated vent valve (Sinon)Pressure operated vent valve (Sinon) 2 NOS-Solenoid safety shut off valve (Sinon) |
|
Each Burner with 2 solenoid valves for LPG |
16 sets of Solenoid valves and flow manual valves | |
Joint Safety | Gas Piping Joints with Standard Copper Jumpers |
|
STANDARD TO BE FOLLOWED | Manufacture the kiln as European standards | |
CONSTRUCTION: |
||
Kiln Structure: | Fabricated steel frame externally clad. Kiln to be manufactured in sections for ease of delivery to site. Kiln Plate should be 304 ss. |
|
Kiln Sheets material: | SS 304,Kiln Plate should be 304 ss. | |
Hood Type: | Moving Hood with 2 side Doors | |
Kiln Hood Lifting and Lowering: | Hydraulic Driven | |
Kiln Hood Movement: | Hydraulic Driven | |
Kiln Both Sides Doors Open and Locking: |
Manual type for swing door to close and open automatic lock by safety unit |
|
Kiln Side Cooling PANELS | Made by galvanize sheet | |
Kiln top access safety | Standard height railing and access ladder to be provided | |
Rails & Channels | Std.Rail with C channels | |
Hydraulic Power Pack position | Provided on side of the hood | |
DAMPERS: | The kiln is of a down draught design and incorporates 2- Slide damper for each flue path of both hearth to open/close automatically. Damper Guide and Door - 310SS |
|
Air Fluel Ratio | Auto adjusted and can be remotely controlled,LTT Confirm Auto Air/Fuel ratio Adjustment | |
FANS: | Noise Level less than 85db tested (1 meter away) . All motors by Siemens, comply to IE3 Including: One kiln combustion fan mounted on the kiln roof One afterburner combustion fan mounted next to the afterburner One exhaust fan To reduce further noise levels of blowers Silencer to be applied |
|
INVERTERS | ABB | |
Control system comprising of a Rittal control panel containing instrumentation control, and kiln over-temperature controller linked to a computer with Scada software acting as the man/machine interface wired to EU colour regulations. Panel A/C included. | ||
OXYGEN LEVEL | Measured by Oxygen Analyzer Yokogawa / NOVATECH, monitor and send signal back PLC (designed to avoid damage by the flue gases below 850ºC, Note: the reading before the resin finish coming out should be not used for proper reading) |
|
HEAT EXCHANGER | One heat exchanger will be mounted after the afterburner for preheating the afterburners | |
CHIMNEY | 18m high from floor level. Upper parts 6mm thick roll plate, bottom 8mm thick roll plate. | |
COOLING | Inject from 16 burners and exhaust from the path under the floor . Ref Volume 10800m³/Hr-14000m³/hr | |
Gas Meter for Kiln: | (China Brand Xun'er) Specifications Mass flow/range--must count in minimum consumption also. & LPG Consumption/cycle theoretical for Direct & Indirect firings to be confirmed during design phase |
|
Cold to Cold Cycle time: | Cooling time to be below 8 hours to get to 400degree from max temperature Reconfirm heating +cooling time & Both end Provision for Cooling system railing/channels. During design phase |
|
Exhaust Connections-Regen | Exhaust Connections for Regen system will be atomized | |
Drawings and documentation | All Drawings of Civil/Electrical/Hydraulics/Mechanical/fabrication/Ladder diagram in English with Commented Programme/Soft Copies also etc Two sets of kiln instruction manual\maintenance manuals |
|
Guarantee | for a period of 12 months from date of first production firing, Burner refractory working life will be 3.5 years for indirect firing |
|
Emmission Level: | match Local Govt. Rules of Pollution Control Board |
|
System Confirmity/Standards | LTT To Confirm --Like NFPA 86,EN 60204-1{SAFETY OF MACHINERY.ELECTRICAL EQUIPMENT OF MACHINES GENERAL REQUIREMENTS,GB/T116618-1996 | |
Training | LTT provide necessity training | |
Ceramic Industry Atmosphere | LTT To Confirm and Consider Dust,Indian Atmosphere Dry & Hot. | |
All parts of Kiln system make, easy availability in indian market | International brands should be first option. (electrical and general parts if necessary) |
|
Equipment Running/Maintaining cost | Running cost will be gas/ electricity consumption depends on firing Maintenance cost will be regularly inspecting burners balls/bricks and kiln seals with floor |
|
Safety related during supply and installation and commissioning. | Method statement /JSA Will be prepared on site and accordingly will be followed. All MCIL EHS Requirements LTT To Fulfill. | |
MACHINE GUARDING | All Moving PARTS must have 360 Deg. Guarding | |
Compensators & Vibration dampers /pads |
where if necessary. |